Description:

Display: 3 3 / 4 digits (4000 counts), 9999 counts (frequency)
Analog bar graph 40-segment
Polarity: Automatic, (-) negative polarity indication
Over-range Indication: Flashes "4000" most significant digit
Low Battery Indication: The battery symbol is shown on the display when the battery voltage is below the operating level
Sampling Rate: 2/seg. nominal; 1/sec. mode capacitance and frequency; 20/seg. to bar graph
Auto Shutdown: After 30 minutes of inactivity
Autorange Fixation Track
Relative mode
Registration MAX / MIN
Data Hold
Operating Environment: 0 ° C to 50 ° C (32 ° F to 122 ° F), RH <70%
Storage Temperature: -20 ° C to 60 ° C (-4 ° F to 140 ° F), RH <80%
Temperature Coefficient: 0.1 x (specified accuracy) / ° C (<18 ° C or> 28 ° C)
Power supply: 9V battery simple
Battery life: 200 hours typical alkaline battery
Safety: According to EN-61010 (IEC-1010)
Input Protection: Installation Category II - 1000V
CE Mark
Dimensions: 189 (H) x 87 (L) x 37 (D) mm.
Weight: Approx. 385g (only the meter), 495g (with Holster)

Voltage DC

Ranges: 400mV, 4V, 40V, 400V and 1000V
Accuracy: ± (0.5% +1 D)
Resolution: 0.1mV, 1mV, 10mV, 100mV, 1V
Input Impedance:> 10MW
Overload Protection: 1000V DC or 750V AC RMS

AC Voltage

Ranges: 400mV, 4V, 40V, 400V, 750V (400mV in manual only)
Accuracy: ± (1.2% +3 D) for 50Hz to 500Hz, ± (2.0% +5 D) 500Hz to 1kHz; * The frequency response for the range of 400mV is only 50Hz to 100Hz
Resolution: 0.1mV, 1mV, 10mV, 100mV, 1V
Input Impedance:> 10MW
Overload Protection: 1000V DC or 750V AC RMS

DC Current

Tracks: 400mA, 20A
Accuracy: ± 400mA (1.0% +1 D), 20A ± (1.5% +1 D)
Resolution: 0.1mA, 10mA
Overload Protection: Fuse on track 0.5A/250V 400mA, High Power Fuse 20A/500V 20A in the range

AC

Tracks: 400mA, 20A
Accuracy: ± 400mA (1.5% +3 D), 20A ± (2.0% +3 D)
Resolution: 0.1mA, 10mA
Frequency response: 50Hz to 500Hz
Overload Protection: Fuse on track 0.5A/250V 400mA, High Power Fuse 20A/500V 20A in the range

Resistance

Ranges: 400W, 4kW, 40kW, 400kW, and 4MW 40MW
Accuracy: ± 400W (1.2% +4 D); 4kW ~ 400kW ± (1.0% +2 D); 4MW 40MW ~ ± (2.0% +4 D)
Open Circuit Voltage: 0.4V DC
Overload Protection: 500V DC or AC RMS

Frequency
Ranges: 100Hz, 1kHz, 10kHz, 100kHz and 400kHz
Accuracy: 1kHz ~ 100kHz ± (0.1% +4 D), 100Hz, 400kHz ± (0.1% +15 D)
Resolution: 0.01Hz, 0.1Hz, 1Hz, 10Hz, 100Hz
Sensitivity: 400mV
Overload Protection: 500V DC or AC RMS

Capacitance

Tracks: 4nF, 40nF, 400nF, 40μF and 4μF
Accuracy: ± 4nF (2.0% +20 D) ~ 40nF 20μF ± (2.0% +4 D) 20μF ~ 40μF ± (5.0% +4 D)
Resolution: 1PF, 10pF, 100pF, 1nF, 10nF
Overload Protection: 500V DC or AC RMS

Temperature

Tracks: -50 ~ 1100 ° C, -50 ~ 2000 ° F
Accuracy: ± (1.0% +2 ° C) ± (1.0% +4 ° F)
Resolution: 1 ° C, 1 ° F
Sensor: Type K Thermocouple
Overload Protection: 60V DC or 24V AC RMS

1 RPM (Motor Conventional) - RPM 2 (DIS)

Tracks: 600 ~ 4000, 1000 ~ 12000 (10 x RPM)
Accuracy: ± (2.0% +1 D)
Resolution: 1RPM, 10 RPM
Effective Reading:> 600 RPM
Overload Protection: 500V DC or AC RMS

Angle Dwele

Ranges: 0 ~ 90 ° (4 cyl.), 0 ~ 72 ° (5 cyl.), 0 ~ 60 ° (6 cyl.), 0 ~ 45 ° (8 cyl.)
Accuracy: ± (2.0% +5 D)
Resolution: 0.1 °
Number of Cylinders: 4, 5, 6 and 8
Overload Protection: 500V DC or AC RMS

Pulse Width (± Trigger)

Range: ~ 0.1ms 10.0ms
Accuracy: ± (2.0% +0.2 ms)
Overload Protection: 500V DC or AC RMS

% Duty Cycle (± Trigger)
Range: 0.0 ~ 90.0%
Accuracy: ± (2.0% +5 D)
Resolution: 0.1%
Pulse Width:> 100ms, <100ms
Overload Protection: 500V DC or AC RMS

Diode Test

Test Current: 0.6mA typical
Accuracy: ± (2.0% +2 D)
Resolution: 1mV
Open Circuit Voltage: 3.0V DC typical
Overload Protection: 500V DC or AC RMS

Audible Continuity

Open Circuit Voltage: 0.4V DC
Audible threshold: <40W Overload Protection: 500V DC or AC RMS

Accessories

Instruction Manual
Test Leads (pair)
Sensor Type K Thermocouple (TPK-01
9V
Shield Holster
Claw for Inductive RPM (HA-149)

Optional

Claw to Current Transformer (CA-600)

Previous: GG