PROVA-5607 Clamp-on Ground Resistance Tester 40mA 116 Records 35mm Jaw

Price: $1,297.77
SKU: 57660
0
diggs
Price in points: 12978 points
Points: 122 points

Our wholesale prices:

Quantity  5+   20+   50+   100+ 
Price  $1,245.86   $1,206.93   $1,180.97   $1,155.02 
Description

- Non-Contact Ground Resistance Measurement
- No Auxiliary Electrode Needed
- Jaw Diameter Φ 35 mm
- 0.025 – 1500 Ohm
- 0.2mA– 35A,True RMS
- 116 Sets of Memory
- Programmable Hi and Lo Alarm
- Programmable Data Logging

APPLICTIONS
- Telecommunication
- Cable TV system
- Electrical Power Plant
- Cellular Phone System
- Factory and Facility
- Gas Station Tank  

Ground Resistance (Auto range)

Range
Resolution
Accuracy of Reading 1,2
0.025 - 0.250 W
0.002 W
± 1.5% ± 0.02 W
0.250 - 1.000 W
0.02 W
± 1.5% ± 0.02 W
1.001 - 9.999 W
0.02 W
± 1.5% ± 0.1 W
10.00 - 50.00 W
0.04 W
± 1.5% ± 0.1 W
50.01 - 99.99 W
0.04 W
± 1.5% ± 0.5 W
100.0 - 200.0 W
0.4 W
± 3.0% ± 1.0 W
200.1 - 400.0 W
2 W
± 5.0% ± 5 W
400.1 - 600.0 W
5 W
± 10% ± 10 W
600.1 - 1500 W
20 W
± 20%

1 Loop resistance noninductive, external field < 200 A/m, external electrical field < 1 V/m, conductor centered.

2 Resistance Measurement Frequency: 1.667KHz,3.333KHz(optional)

Ground/Leakage Current (Auto range, 50/60 Hz, True RMS, Crest Factor < 3.5)

Range
Resolution
Accuracy of Reading
0.200 - 1.000 mA
0.001 mA
± 2.0% ± 0.05 mA
1.00 - 10.00 mA
0.01 mA
± 2.0% ± 0.03 mA
10.0 - 100.0 mA
0.1 mA
± 2.0% ± 0.3 mA
100 - 1000 mA
1 mA
± 2.0% ± 3 mA
0.20 - 35.00 A(5637)
0.01A
± 2.0% ± 0.03A
0.20 - 15.00 A(5601)
0.01A
± 2.0% ± 0.03A
0.20 - 30.00 A(5601)
0.01A
± 3.0% ± 0.03A

General Specification

Accuracy of Resistance Calibration Plate ±0.5%
Data Logging Capacity 116 records
Data Logging Interval 1 to 255 seconds
Conductor Size 35mm /1.38”(5637), 23mm /0.90”(5600,5601)
Jaw Opening 38mm /1.49”(5637), 27mm /1.06”(5600,5601)
Battery Type 9V IEC 6 LR61 (Alkaline)
Display Type 4 digits 9999 counts LCD
Overload Indication OL
Battery Life 3000 measurements
Low Battery Indication  
Range Selection Auto
Power Consumption 40mA
Sampling Time 0.5 seconds
Operating Temperature 0 ℃ to 50 ℃ (14 ℉ to 122 ℉ ) Operating Humidity: Less than 85% RH
Storage Temperature -20 ℃ to 60 ℃ (-4 ℉ to 122 ℉ ) Storage Humidity: Less than 75% RH
Dimension 276mm (L) x 100mm(W) x 47mm(H),10.8" (L) x 3.9"(W) x 1.9"(H)
Weight 750g/1.65lbs
Accessories
  • Resistance Calibration Plate x 1
  • Battery 9V (Installed) x 1
  • Carrying Box x 1
  • Users Manual x 1