Description

- Analysis for 3P4W, 3P3W, 1P2W, 1P3W
- True RMS Value(V 123 and L 123 )
- Active Power(W, KW, MW, GW)
- Apparent and Reactive Power (KVA, KVAR)
- Power Factor (PF), Phase Angle (Φ)
- Energy (WH, KWH, KVARH, PFH)
- Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
- Display of 35 Parameters in One Screen(3P4W)
- rogrammable CT (1 to 600) and PT (1 to 3000) Ratios
- Display of Overlapped Voltage and Current Waveform
- 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
- Output of Waveform, Power Parameters and Harmonics at Command
- Large Dot Matrix LCD Display with Backlight
- Average Demand (AD in W, KW, MW)
- aximum Demand (MD in W, KW, MW) with Programmable Period
- Harmonic Analysis to the 99th Order
- Display of 50 Harmonics in One Screen with Waveform
- Display of Waveform with Peak Values (1024 Samples/Period)
- Analysis of Total Harmonic Distortion (%THD-F)
- Graphic Phasor Diagram with 3 Phase System Parameters
- Capture 28 Transient Events (Time+Cycles) with Programmable Threshold(%)
- 3 Phase Voltage Unbalance Ratio (VUR)
- 3 Phase Voltage Unbalance Factor (d0%, d2%)
- Calculated Unbalance Current through Neutral Line (In)
- Optical isolated USB Interface
- Built-in Timer and Calendar for Data Logging
- onductor Size: Model 6801 30mm(approx)

Please refer to users manual for more detailed and up-to-date description of specification

AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1)

 
Range
Resolution
Accuracy of Readings

6800+6801

(Overload Protection AC200A)

0.050 – 9.999A
0.001A
±0.5% ± 5dgts
10.00 – 60.00A
0.01A
±0.5% ± 5dgts
60.00 – 99.99A
0.01A
±1.0% ± 5dgts

AC Current( 50 or 60Hz, Auto RangeTrue RMSCrest Factor<4CT=1) 

Range
Resolution
Accuracy of Readings

6800+6801

5.0 – 999.9W
0.1W
±1% ± 8dgts
1.000 – 9.999 KW
0.001 KW
±1% ± 8 dgts
10.00 – 99.99 KW
0.01 KW
±1% ± 8 dgts
100.0 – 999.9 KW
0.1 KW
±1% ± 8dgts
1000 – 9999 KW
1 KW
±1% ± 8dgts

AC Voltage (50 or 60 Hz, Auto Range, True RMS, Crest FActor<4)

Range
Resolution
Accuracy of Readings
Range
Resolution
Accuracy of Readings

4.0V – 500.0 (Phase to Neutral)

0.1V

± 0.5% ± 5dgts

4.0V –600.0V (Phase to phase)

0.1V

± 0.5% ± 5dgts

Harmonics of AC Voltage in % and in Magnitude (1 to 99th order, minimum voltage at the 50 or 60 Hz>AC 80V)

Range
In Percentage
In Magnitude
Resolution
Accuracy of readings
Resolution
Accuracy of readings
1 – 20 th

0.1%

±2%

0.1 V

±2% ±0.5V
21 – 49 th
4% of reading ±2.0%
4% of reading ±0.5A
50 – 99 th
6% of reading ±2.0%
6% of reading ±0.5A

Harmonics of AC Current in % and in Magnitude

Model 6800+6801(100A)(1 to 99th order, minimum current at 50 or 60 Hz is greater than 10% of the range)

 

Range
In Percentage
In magnitude
Resolution
Accuracy of reading
Resolution
Accuracy of reading
1 – 10 th

0.1%

±0.2 of reading ±1%
0.1mA / 0.1A
±0.2% of reading ±7dgts
11 – 20 th
±2% of reading ±1%
±2% of reading ±7dgts
2 1 – 50 th (A range)
±5% of reading ±1%
±5% of reading ±7dgts
2 1 – 50 th (mA range)
±10% of reading ±1%
±10% of reading ±7dgts
5 1 – 99 th
±35% of reading ±1%
±35% of reading ±7dgts

Total Harmonic Distortion

Range
Resolution
Accuracy(6801)
0.0 – 20%
0.1%
±1%
20 – 100%
0.1%
±3% of reading ±5%
100 – 999.9%
0.1%
±10% of reading ±10%

Peak Value of Ac Voltage or AC Current ,VT=1

Range
Samping Time
Accuracy of reading
50Hz
39 μS
±5% ±30digits
60Hz
33 μS
±5% ±30 digits

Crest Factor (C.F.) of ACV or ACA ,VT=1

Range
Resolution
Accuracy of reading
1.00 – 99.99
0.01
±5% ±30digits

Frequency in AUTO mode

Range
Resolution
Accuracy of reading
45 – 65Hz
0.1Hz
0.1Hz

Power Factor (PF)

Range
Resolution
Accuracy of reading
0.00 – 1.00
0.01
± 0.04

Phase Angle (Φ)

Range
Resolution
Accuracy of reading
-180 to 180
0.1
± 1

General Specification

Conductor Size (6801) 30mm (approx)
Battery Type 1.5V SUM-3 x 8
Display Dot Matrix LCD with backlight
Power Consumption 140mA (approx.)
External DC Input DC 12V adaptor (for safety purpose, the adaptor must be certified with 600Visolation protection)
LCD update rate 1 times / sec
No. Of Samples/Period 1024
Operating Humidity < 85% relative
Operating Temperature -10°C to 50°C
Storage Humidity < 75% relative
Storage Temperature - 20°C to 60°C
Weight(6801) 200g
Dimension(6801) 210 (L) x 62 (W) x 36 (H) mm ,8.3 " (L) x 2.5" (W) x 1.4" (H)
Accessories test leads x 4alligator clips x 4Carrying bag x 1Users manual x 1Batteries 1.5V x 8

Previous: PROVA-6800+6802 Power and Harmonics Analyzer (1000A) True RMS Built-in Timer and Calendar

NextPROVA-6601 AC+DC 3 Phase Power Clamp Phase 2 x 4 Digits Dual Display LCD 25mA

Reviews
Write a ReviewPost PhotosPost Videos, and get GoodLuckBuy points!


No posts found
 

Discussions

Loading...
122